Home Energy Magazine Online March/April 1993
METERING TOOLS
`Read Me Your Thermostat':
Short-Term Evaluation Tools
by Laurence F. Kinney
Laurence F. Kinney is president of Synertech Systems Corp., an energy
research and services organization in Syracuse, N.Y.
Installing and using run-time meters
the right way, in concert with well-planned weekly calls to meter reading
clients, can provide effective evaluation of weatherization work.
It's not easy to measure savings from energy conservation work,
yet it is crucial for a job well done. Many of the problems facing evaluations
based on fuel savings result from the time required to collect adequate
consumption data. Evaluation designers generally believe it's important to know
household fuel usage for as much of the heating season (and non-heating season,
to establish baseline consumption) as possible prior to weatherization and for
as long as possible after that. They consider 18 months an adequate time span
for gathering data. In fact, data is seldom collected over an 18-month period.
To save time, the crucial before-weatherization data that provides the base
from which savings are calculated is usually gathered from records kept for
other purposes, such as meter-based utility bills.
An approach which shows particular promise makes extensive use of simple and
inexpensive instrumentation to measure quickly--over weeks, not months--how
weatherization changes the efficiency of dwellings. This approach lends itself
to large numbers of dwellings and is quite suitable for agency staff and others
who may not have technical backgrounds. This approach does not measure
"savings" at all, but rather enables one to project what savings can reasonably
be expected barring major changes in occupancy or behavior. Utilizing
short-term consumption data can, in turn, help estimate appropriate levels of
weatherization investment. The tools must fit the approach (see accompanying
article, "Keeping A Running Score on Weatherization,").
Elapsed Timers
Most furnaces and boilers used for residential heating are either off or
on, and when on, they consume energy at a constant rate. Measuring the rate of
consumption is fairly straightforward. In the case of natural gas, watching,
with a stopwatch in hand, the dials turn on the gas meter while the furnace
(and only the furnace) is firing yields sufficiently accurate data on
firing rate. For oil furnaces, that rate can be determined with sufficient
accuracy by pulling the burner and examining the flow rate etched on the nozzle
in gallons per hour. (The Btu in fuel oil or natural gas can vary by up to 3%,
so precision is quite difficult to achieve.)
If one knows the rate of consumption of a furnace or boiler, then by measuring
the time it is operated over a given period in which outside temperature is
tracked, it is possible to produce a simple but useful weather-adjusted index
of consumption, Btu per heating degree-day (Btu/HDD). This is calculated by the
elapsed time multiplied by the firing rate of the furnace (or boiler), all
divided by the heating degree-days for the appropriate reference temperature
over the same period. Dividing by the heated area gives the energy intensity
(Btu/ft2-HDD).
Over the last 12 years, Synertech has used elapsed timers to determine savings
due to both building shell and HVAC system retrofits. Under most circumstances,
we prefer simple electro-mechanical devices that use 24VAC (alternating current
voltage) synchronous motors to drive mechanical wheels calibrated in hours and
tenths of hours. These are widely available for $10-$40 (see box, "Short-Term
Metering Equipment Makers," p. 37).
Gas Furnaces
In the case of natural gas or propane-fired furnaces or boilers, the
elapsed timer is wired in parallel with the gas solenoid valve (see Figure 1).
When the current flows in the gas solenoid, the valve opens, gas flows, and the
timer begins. When the thermostat is "satisfied," the gas solenoid valve closes
and the timer quits registering time. Since the timer we recommend is a
mechanical device rather than digital, power outages will not cause a loss of
data.
Oil Furnaces
In the case of oil-fired furnaces, it is sometimes possible to work at
24VAC , but we prefer to measure when the motor that pumps oil (and air) is
actually running. We use a transformer, housed in a small box with a fuse, as
an intermediary between the oil burner and the timer. The 120 VAC primary
(input) of the transformer is wired in parallel with the oil burner motor, and
the 24VAC secondary (output) is wired to the timer. In practice, the
transformer is located 6-10 ft from the burner--frequently mounted to a solid
joist above the furnace--and is connected to the burner with a flexible,
armored BX cable. The timer, on the other hand, is located where the client can
read it conveniently--usually in the living area, close to a telephone. We use
ordinary thermostat wire to connect the timer to the transformer box (or the
furnace in the case of gas). Office staff then can call the client weekly to
check readings and calculate the week's consumption for that house using a
simple worksheet.
The Thermostat As Data-Logger
A new generation of set-back thermostats have several advantages over
elapsed timers. Chief among the advantages is the ability to store the
cumulative time that the thermostat "calls" for heat. Several models produced
by the Hunter Fan Co. feature a review function that provides the total elapsed
time the thermostat calls for heat "today," "yesterday," "this week," and "last
week," where a week ends at midnight Sunday. A "filter review" command totals
the time the system has run, up to 1,000 hours of firing time--a feature
intended to prompt the homeowner to change the furnace filter, but useful for
our purposes as well.
Installing a thermostat is easier than installing an elapsed timer, the readout
is more accurate, and the recorded time periods are identical for all users
(midnight Sunday to midnight the following Sunday). For weatherization
programs, it may be counted as a material expense, thereby reducing the
material expense for "evaluation" to zero. (For disadvantages of using the
Hunter thermostat this way, and alternative wiring methods, see box "The Hunter
Thermostat As Logger--Special Cases.")
Filling Out The Audit Forms
Before The Calling Begins--and In Between
Several things need to be in place before taking the weekly client
readings of the elapsed timers or thermostats. Let's look at a typical house
assuming that the crew installed Hunter's Auto Temp or Energy Monitor II Plus
thermostat (or equivalent) during the audit and that the client agreed to
receive weekly phone calls to report the previous week's consumption. (In the
case of clients without phones, using a pre-addressed and pre-stamped postcard
is adequate.)
On that initial visit, the auditor will begin filling out the form (see Figure 2):
The firing rate (Btu/hr) for furnaces using natural gas is determined by
measuring the time for a full rotation of the 1 ft3 or 2
ft3 dial on the gas meter while only the furnace is firing. Assuming
that 1 ft3 of natural gas has an energy content of 1,000 Btu, the
auditor determines the cubic feet per hour of gas flow which then is multiplied
by 1,000 to yield the firing rate in Btu per hour. The auditor compares the
firing rate, determined by the timing method, to the label on the furnace. If
there is a significant difference, the procedure is repeated.
The fuel dispersion nozzle in an oil-fired heating system is inscribed with the
rate at which the nozzle will allow oil to flow in gallons per hour (for a pump
pressure of 100 psi). The flow rate multiplied by the Btu capacity of the fuel
(approximately 140,000 in the case of No. 2 grade of fuel oil) gives the Btu/hr
firing rate of the system.
Firing rates for furnaces using propane are read directly from the label on the
furnace itself.
The house floor area (ft2), used to calculate energy
intensities, should include only deliberately conditioned areas, not the
basement or attic unless each is heated.
Heating degree days (HDD), should be determined and recorded on a
calendar each day, using a reference temperature of 65deg.F. A local weather
station can provide daily readings, but other sources such as newspapers are
also adequate. The problems with National Weather Service data are the
four-month delay in delivery of the data, the possibility of a significant
distance between the audit site and weather station, and the unwieldy format of
the data on the diskette provided by the weather service. (Synertech Systems
Corp. offers a special weather station with accompanying software that updates
local heating degree-day files automatically.)
The point is to have a consistent, reliable source of temperature data from a
location close to the monitored dwellings. The average temperature for a
24-hour day (the mean of the high and low is satisfactory for these purposes)
is subtracted from 65 (if the reference temperature is 65deg.F) to determine
the heating degree-days in a specific day. Only positive values are used; in
other words, if the average temperature is higher than 65deg.F, there are no
heating degree-days that day.
The auditor should fill in the sum of heating degree-days from last Monday
through the most recent Sunday (column 10) before telephoning the client, and
this number should be stored in the memory of a hand calculator.
Over The Phone--and Afterwards
The auditor obtains other information during the phone call to the
client (columns 1-7), with the remaining calculated after the call (columns 8,
9, 11, and 12).
Although it is not essential for calculating weekly consumption, we recommend
that the client be asked to read out the current room temperature, and
to then push the filter review button briefly to read the total
firing time since reset or installation. Temperature information is useful in
tracking client thermostat-controlling behavior. The caller can use total
information from the filter review command to reconstruct a missed week of
information. One drawback of the Hunter thermostat and logger is that it
displays information for 10 seconds after one pushes a button, but holding a
button down for more than 3 seconds erases the data!
The information in the last column, Btu per HDD per ft2,
should be monitored with each weekly call to spot irregularities. Variations of
more than 30% from week to week should prompt double checking of calculations,
and then calling the client to verify the reading or check on any changes in
lifestyle. (Did the furnace quit working? Were the grandchildren around the
house for most of the week?) If circumstances appear out of the ordinary in the
household, it may be wise to exclude that week's data from the analysis, but
only if a clear explanation for the anomaly is recorded. Using this type of
audit form with weekly calls thus has the effect of performing important
quality control checks on the data base, as well as preemptively solving
individual mysteries.
What Works
Our experience has shown that elapsed timers coupled with human contact
are the most important ingredients of the short-time approach. The basic
equipment for this approach includes:
The caller should be well prepared before the first telephone call to the
client, with the audit form primed with information for weather-normalization,
firing rates, and heated area of the house. With information on run-time
reported by the client, the caller can calculate the weekly energy intensity,
before and after weatherization takes place, and can make short work of
evaluating the cost-effectiveness of the retrofit work.

Figure 1. Schematic of elapsed-time meter installation to measure
furnace firing time. Meter indicates 8 hours, 43 minutes of furnace
on-time.
The Hunter Thermostat As Logger--
Special Cases
The Hunter set-back thermostat can used as a short-term monitoring tool,
but it may not be appropriate in some circumstances. In some cases,
alternatives are possible, in others not:
Some people are intimidated by digital thermostats. In this case,
another monitoring technique necessary, like installing an elapsed timer with a
remote read-out in the living area.
A furnace hits its high temperature limit and turns off prior to the
thermostat being satisfied. Since the thermostat counts the time that it
"calls" for heat, in this case it will overestimate energy consumed by the
furnace. The auditor should fix this problem on the initial visit by repairing
a defective fan motor, broken belt, or dirty heat exchanger, or increasing the
air flow across the heat exchanger by cleaning a dirty filter or unblocking
ducts.
The heating system operates on millivolts. Millivolt systems are usually
found in old gas-fired furnaces or boilers. The pilot light heats a thermopile
that produces about 0.7VDC (direct current voltage), used in a series circuit
with the thermostat and solenoid valve to activate the heating system.
Thermostats that control millivolt systems cannot use anticipators, and thus do
not operate the heating system as efficiently as thermostats that include
anticipators. (The Hunter has an electronic anticipator set for a 3deg.F dead
band.)
We recommend retrofitting millivolt furnace systems to operate on 24VAC
(alternating current voltage) as an energy saving measure. It requires a 24V
transformer wired in a series circuit with the new thermostat and the coil of a
relay. The poles of the relay substitute for the switch on the old thermostat.
Thus, when the thermostat calls for heat, it closes a relay which in turn
closes the low-voltage system circuit, opening the gas solenoid valve.
Honeywell makes a millivolt system conversion package--a transformer/relay
combination that mounts on a standard electrical box--for around $20, and
installation is fairly simple.
Electric heat is controlled by a single thermostat. Electric furnaces
work just like oil- or gas-fired furnaces. Be sure that the firing rate is
constant before bothering to install a Hunter thermostat. (The firing rate is
usually listed in kilowatts on the furnace label; multiply by 3,413 Btu/kWh, a
standard conversion factor, to get Btu/hr.)
Caution: Whenever working on thermostats associated with electrical heating,
use a volt-ohm meter to verify the presence of 24V, not 120V which can shock or
electrocute the unaware installer!
Some thermostats associated with cheap but common electric-fired systems
are designed to operate at line voltage, 120V, but the Hunter thermostats are
designed for only 24V operation. Convert the old thermostat to the Hunter by
using a transformer and relay, similar to the conversion for millivolt
systems.
The dwelling has electric heat with multiple thermostats. Instead of
installing a new thermostat for estimating consumption, rely on utility
bills.
A hot water boiler serves a single zone. In a system like this, the
thermostat doesn't fire the boiler directly, but rather activates a circulation
pump that moves water from the boiler to the radiators and back. The boiler
fires when its water cools to the point where an aquastat calls for heat. Thus,
the run time of the circulation pump is proportional to the firing time
of the boiler, but it is not identical to it. One would expect the differences
to vary with outside air temperature and with the length of firing cycle, but
the variations may not be large. If they are small, then it should be possible
to determine weatherization savings by measuring the water circulation pump
on-time using the energy usage feature on the thermostat.
In order to study the possibility of measuring savings in systems of this kind,
it's easy to install some simple instrumentation to measure the differences.
This would consist of a Hunter thermostat and a combination elapsed time meter
and event counter hooked directly to the solenoid that fires the burner on the
boiler. It also requires a homeowner who is willing to read three dials instead
of just one.
A hot-water boiler serves more than one zone for space heating. We
recommend not bothering installing a new thermostat.
The house has a condensing furnace. The operation of a condensing
furnace (all new furnaces of 78% AFUE and higher, except pulse, use induced
fans and have a pre-fire purge) can cause errors in measuring consumption with
the thermostat method. Typically, when the thermostat calls for heat, instead
of firing immediately, a small fan switches on to pull fresh air through the
heat exchanger prior to opening the gas valve. This "purge cycle" lasts up to
45 seconds, so the firing time recorded by the thermostat overstates reality by
as much as 45 seconds, multiplied by the number of firing cycles between
readings. But since typical firing time is about 10 minutes, the error is less
than 10%.
For purposes of calculating percentage savings due to weatherization, this
problem may be safely ignored, since savings are given by the ratio of
consumption before and after conservation. However, since after-weatherization
furnace run-times should be slightly shorter, the effect of ignoring the purge
time in the calculation should understate (to a minor degree) estimates of
percentage savings. Absolute savings figures would also be in error. Therefore
the new thermostat should be installed on all furnaces with induced draft fans.
(It is important to install event counters on a sample of the monitored homes
so that a good working number for the number of firing cycles versus firing
times before and after weatherization may be derived from a representative
sample of dwellings.)
Interaction Between Timer and Anticipator
There can be a subtle interaction with the thermostat when an elapsed
timer is wired in parallel with the solenoid. The timer raises the overall
current that flows through the thermostat when the furnace calls for heat. The
result is the anticipator producing slightly more heat than it produces without
the timer in the circuit, thereby decreasing the firing time of the furnace.
What is the anticipator? Here's what we wrote in Home Energy:
"The anticipator in most conventional thermostats is in fact a little
resistance heater located very close to the temperature-sensitive bimetallic
strip itself. It warms the space around the thermostat element.... The
anticipator "fools" the thermostat element into believing that the room
temperature is warmer than it really is, so the furnace is switched off.
"The anticipator is necessary because of thermal mass, [in other words,] hot
air in the ducts (or hot water pipes), heat remaining in the heat exchanger,
and an uneven distribution of heat in the house...The anticipator turns off the
furnace before the room air temperature reaches the desired setting because,
with the heat from addition thermal mass evenly distributed, the room
temperature will stay within the limits of the desired temperature. If the
thermostat simply waited until the room temperature reaches the thermostat
settings before shutting off the furnace, the residual heat in the system would
result in "coasting" to well above the desired temperature." (From
"Anticipators: Completing the Feedback Loop," HE Mar/Apr '87, p. 30)
ln practice the additional anticipator heat is insignificant, particularly if
one picks an elapsed timer which draws only a small amount of current. However,
it's worth measuring to be certain, and adjusting the anticipator if needed.
Short-Term Metering Equipment Makers
Elapsed Timers
Kessler Ellis Products
120 First Ave.
Atlantic Highlands,
NJ 07716
Tel: (800)631-2165
Fax: (908)291-8097
Newark Electronics
4801 N. Ravenswood Ave.
Chicago IL 60640
Tel: (312)784-5100
Fax: (312)907-5211
Thermostat
Hunter Fan Co.
2500 Frisco Ave.
Memphis, TN 38114
Tel: (901)745-9222
Fax: (901)745-9385
North Fork Retrofit
511 Carpenter St.
Greenport, NY 11944
Tel & Fax: (516)477-2922
Redington Counters Inc.
130 Addison Rd.
P.O. Box 608
Windsor, CT 06095
Tel: (203)688-6205
Fax: (203)688-1591
Millivolt Furnace Retrofit Kit
Honeywell Inc.
1985 Douglas Dr.
Golden Valley, MN 55422
Tel: (800)328-5111

Figure 2. Weekly run-time audit form
Related Articles
"Keeping a Running Score on Weatherization" (Hill) "Measuring the Performance of the National Energy Audit" (Sharp) "Moisture and Mobile Home Weatherization" (Tsongas) "Profiles of Multifamily Weatherization Projects: A Tale of Five Cities" (Kinney, Wilson, and MacDonald) "Selecting an Infrared Imaging System" (Snell) "Ten Highly Effective Weatherization Programs" (Brown and Berry) "Weatherization Assistance: The Fuel Oil Study" (Ternes and Levins) "Weatherization Assistance: The Single-Family Study" (Brown and Berry) "The Best Boiler and Water Heating Retrofits" (Lobenstein and Hewett) "Combustion Safety Checks: How Not to Kill Your Clients" (deKieffer) "Condensing Furnaces: Lessons from a Utility" (Beers) "Don't Force Air, Go with the Flow" (Springer) "Downsizing Steam Systems" (Gifford) "Fireplaces: Studies in Contrasts" (Hayden) "Integrated Heating and Ventilation: Double Duty for Ducts" (Jackson) "The Key to Persistence" (Nolden) "Remodeling Bathrooms: Let the Energy Savings Flow" (Johnston) "Making Low-income housing Affordable: The Northgate Retrofits" (Patullo)